Incoming material
Copper conductor resistance, insulation thickness, compound hardness and colour are checked against the mill certificate for every reel. Non-conforming reels are quarantined and returned, not re-graded.
Every cord that leaves the plant has been electrically tested. That is the floor, not the ceiling: incoming material control, in-process inspection and batch traceability sit behind it.

Copper conductor resistance, insulation thickness, compound hardness and colour are checked against the mill certificate for every reel. Non-conforming reels are quarantined and returned, not re-graded.

First-off approval at each shift start, hourly dimensional checks on pin spacing and housing, and crimp pull-force monitoring on every cycle.

100 % hipot at 1 500 V AC / 1 s for Class II, 100 % earth continuity below 0,1 Ω for Class I, and polarity check on every piece. AQL 0,65 sampling on top.

Each carton carries a production order number that links back to the cable reel, tool, machine, operator shift and test record. Batch records are kept for five years.
Send a drawing, a sample or just a description. Our engineers reply with a feasibility assessment and indicative pricing within two working days.